The Sit-to-Stand Test: What Research Says About the Chair Rise Test and Longevity in 2027

Quick Answer
The sit to stand test is simple: sit on the floor, then stand back up — without using your hands, your knees, or anything else for support. In a study of 4,282 adults aged 46 to 75, followed for a median of 12.3 years, the people who could do that cleanly, scoring a perfect 10 out of 10, died at a rate of 3.7%. The people who scored 0 to 4 — about one in ten of the group — died at a rate of 42.1%. After adjusting for age, sex, body mass and clinical variables, the lowest-scoring group carried nearly four times the risk of dying from natural causes (hazard ratio 3.84) and six times the risk of dying from cardiovascular disease (hazard ratio 6.05) compared with the perfect scorers.
The same test, in a smaller and earlier study of 2,002 adults, told the same story: the lowest scorers died at more than five times the adjusted rate of the highest scorers (hazard ratio 5.44), and every extra point on the 10-point scale was linked to a 21% improvement in survival. And the chair version of the test — standing up from a chair five times, timed — carries the same signal in far bigger numbers: in 43,605 adults across Europe, the slowest fifth took 18 seconds and carried an 18% higher mortality risk than the middle, while the fastest fifth took 7 seconds and carried a 26% lower risk.
The number is a signal, not a sentence. A low score does not mean a short life, and a perfect score does not guarantee a long one. Every study in this article is observational: researchers watched people and recorded what happened. No study tested whether practising the test, or training leg strength, changes how long anyone lives. Rising from a chair or the floor is something most people do dozens of times a day without thinking about it — and that ordinariness is exactly why it works as a test. It asks strength, power, flexibility, balance and body composition to cooperate at once, and the result is the sum of all of them.
Key Takeaways
- The floor test, 4,282 people, 12 years: perfect scorers (10/10) died at 3.7%; the lowest group (0–4) died at 42.1% — an eleven-fold gap in raw death rates, and an adjusted hazard ratio of 3.84 for natural mortality and 6.05 for cardiovascular mortality.
- The first study said the same thing: in 2,002 adults, the lowest scorers carried a 5.44× adjusted mortality risk vs the highest scorers, and each extra point on the scale meant 21% better survival.
- The chair version works at scale: in 43,605 adults, five chair stands in 7 seconds meant a 26% lower mortality risk than the median 11 seconds; 18 seconds meant an 18% higher risk.
- Grip was slightly stronger — honestly: in the same 43,605-person study, weak grip predicted death more strongly than a slow chair stand, but the chair stand was especially useful in women. Both tools are valuable; neither replaces the other.
- Three tests share one name: the floor sitting-rising test (scored 0–10), the 5-repetition chair stand (timed in seconds) and the 30-second chair stand (counted in 30 seconds) are different tests with different numbers. This article keeps them apart.
- There is no personal pass mark: the studies describe population survival in specific age groups (46–75 in the floor test, 50+ in the chair studies). No study sets a score or a time you must reach.
- The evidence is observational: no trial shows that improving your sit-to-stand score reduces your risk of dying. That is the honest limit on every number here.
Three Tests, One Name
“Can you stand up from a chair?” sounds like one question. In the research literature it is three different questions, asked three different ways, with three different kinds of answer — and the first thing this article has to do is keep them apart, because their numbers cannot be compared with each other.
The first is the sitting-rising test, or SRT. You sit on the floor, cross-legged if you like, and then stand back up — without using a hand, a forearm, a knee or the side of your leg for support, and without wobbling. You start with 5 points for sitting down and 5 for getting up, and you lose a point for every support you use and half a point for an unsteady movement. The result is a score from 0 to 10. There is no stopwatch. The test measures how you move, not how fast you move.
The second is the 5-repetition chair-stand test, or 5-CST. You sit in a chair, cross your arms over your chest, and stand up and sit down five times as quickly as you can. The result is a time in seconds. In the two large European studies in this article, the middle time was 11 seconds — the fastest tenth of people took 7 seconds, the slowest tenth took 18 or 19 seconds.
The third is the 30-second chair-stand test. Same chair, same crossed arms, but now the question is how many full stands you can complete in 30 seconds. The result is a count. The US Centers for Disease Control and Prevention includes it in its STEADI fall-prevention toolkit, with below-average scores listed by age and sex for adults aged 60 to 94 — for example, fewer than 14 stands for men aged 60 to 64, and fewer than 12 for women the same age.
| Test | What you do | Result | Where it is used |
|---|---|---|---|
| Sitting-rising test (SRT) | Sit on the floor and rise, no support | Score, 0–10 | Research clinics; the mortality studies in this article |
| 5-repetition chair stand (5-CST) | Stand up and sit down 5 times, as fast as you can | Time in seconds (median 11 s) | Large population studies (SHARE, 43,605 and 18,252 people) |
| 30-second chair stand | Stand up and sit down as many times as you can in 30 seconds | Count of stands | CDC STEADI fall-risk screening, ages 60–94 |
The rest of this article names the test every time it quotes a number, because a score of 8, a time of 11 seconds and a count of 12 stands are three different things that happen to share a name. When the studies agree — and they do, in direction, across all three versions — that agreement means more precisely because the tests are different: it is not one measurement repeated, but three ways of watching the same system work.
The 2025 Study: 4,282 People, 12 Years
The headline study of this article was published online on 18 June 2025 in the European Journal of Preventive Cardiology, and it is the largest and longest study of the floor sitting-rising test ever done. It comes from the CLINIMEX Exercise Clinic in Rio de Janeiro, Brazil, led by Claudio Gil Araújo — the same clinic, and largely the same team, that ran the original 2012 study. Thirteen years after the first result, they returned with more than twice as many people and twice as long a follow-up, and asked a sharper question: does the test predict not just death in general, but death from natural causes and from cardiovascular disease specifically?
The participants were 4,282 adults aged 46 to 75, 68% men, who came to the clinic for a medical evaluation focused on physical fitness between 1998 and 2023. None of them had locomotor or musculoskeletal complaints that would have made the test unsafe or impossible — this matters, because it means the study measured the test in people who could reasonably be asked to do it, not in people already too ill to get on the floor. Each person sat on the floor and rose again, barefoot, on a non-slippery surface, in a space of about 2 by 2 metres. Crossing the legs was allowed. Using the side of the foot as a support was not.
The scoring is exact, and worth understanding, because the whole result hangs on it. You start with 5 points for sitting and 5 for rising. You lose 1 point for each support you use — a hand, a forearm, a knee, the side of a leg. You lose 0.5 points for an unsteady execution. A perfect score of 10 means you sat down and stood up cleanly, with no support and no wobble. The researchers then grouped the scores into five bands: 0–4, 4.5–7.5, 8, 8.5–9.5, and 10.
Over a median follow-up of 12.3 years, 665 people died from natural causes — 15.5% of the group. Deaths from COVID-19 and from external causes, such as accidents, were excluded, so these are deaths from disease, not from chance. And the death rate rose steadily as the score fell:
| SRT score group (Araújo et al. 2025, 4,282 people, median 12.3 years) | Deaths from natural causes | What it means |
|---|---|---|
| 10 (perfect) | 3.7% | Fewer than 1 in 25 died |
| 8.5–9.5 | 7.0% | About 1 in 14 died |
| 8 | 11.1% | About 1 in 9 died |
| 4.5–7.5 | 20.4% | About 1 in 5 died |
| 0–4 (lowest) | 42.1% | More than 2 in 5 died |
The chart below shows the same five bars, so the shape of the relationship is visible at a glance. It is not a cliff — there is no single score where the risk suddenly jumps. It is a slope, and it runs the whole length of the scale.
Deaths from natural causes over a median 12.3 years, by sitting-rising test score — Araújo et al. 2025
Score 10: 3.7%
Score 8.5–9.5: 7.0%
Score 8: 11.1%
Score 4.5–7.5: 20.4%
Score 0–4: 42.1%
Source: Araújo et al., European Journal of Preventive Cardiology 2025; 4,282 adults aged 46–75. Bar widths are proportional to the percentages. COVID-19 and external-cause deaths excluded.
Two ways of reading the gap, and the difference between them matters. In raw terms, 42.1% divided by 3.7% is about 11.4 — the lowest-scoring group died at more than eleven times the raw rate of the perfect scorers, and the group scoring 8 died at three times the raw rate (11.1% vs 3.7%). But raw rates do not account for the fact that the low scorers were also older and sicker. The researchers adjusted for age, sex, body mass index and clinical variables, and the adjusted figures are smaller — and more honest. Comparing the lowest group with the perfect scorers, the adjusted hazard ratio was 3.84 (95% CI 2.25–6.97) for natural mortality and 6.05 (95% CI 2.29–20.94) for cardiovascular mortality. In plain terms: after stripping out the effects of age, sex, weight and existing illness, the lowest scorers still carried nearly four times the risk of dying from natural causes and six times the risk of dying from cardiovascular disease.
That is the number to carry away from this study — 3.84 and 6.05, not 11.4. The raw gap is real, and it is dramatic, but it mixes together the effect of the test with the effect of everything else that makes low scorers different. The adjusted figure is the study’s own answer to the question “how much does the score itself add?” And the answer is: a lot. The authors’ conclusion is plain: non-aerobic physical fitness, as assessed by the sitting-rising test, was a significant predictor of natural and cardiovascular mortality, and the test — which is influenced by muscular strength and power, flexibility, balance and body composition — could add relevant clinical and prognostic information to routine examinations.
One more detail from the study’s plain-language summary is worth noting. About one in ten participants scored in the lowest band (0–4). This was not a rare result in a small corner of the group. It was a tenth of 4,282 adults who had walked into an exercise clinic — people well enough to be assessed, and a tenth of them could barely sit and rise from the floor.
The First Study: 2,002 People in 2012
The 2025 study did not come out of nowhere. It is the follow-up to a smaller, earlier study from the same clinic, published online on 13 December 2012 and in print in 2014, also in the European Journal of Preventive Cardiology. That first study is the one that put the sitting-rising test on the map — and it is worth reading on its own, because it shows that the 2025 result is not a one-off. Two studies, thirteen years apart, same test, same clinic, same direction.
The 2012 study included 2,002 adults aged 51 to 80, again 68% men, who performed the same test: sit on the floor and rise, scored from 0 to 10, one point lost for each support used. The researchers grouped the scores into four bands this time — 0–3, 3.5–5.5, 6–7.5, and 8–10 — and followed the group for a median of 6.3 years. In that time, 159 people died — 7.9% of the group.
The pattern was the same, and the adjusted figures were, if anything, larger:
| SRT score group (Brito et al. 2012/2014, 2,002 people, median 6.3 years) | Adjusted hazard ratio vs the 8–10 group | What it means |
|---|---|---|
| 0–3 (lowest) | 5.44 (95% CI 3.1–9.5) | More than five times the mortality risk |
| 3.5–5.5 | 3.44 (95% CI 2.0–5.9) | More than three times the risk |
| 6–7.5 | 1.84 (95% CI 1.1–3.0) | 84% higher risk |
| 8–10 (highest) | 1.00 (reference) | The comparison group |
These hazard ratios are adjusted for age, sex and body mass index, so they already strip out the most obvious confounders. And the study reported one more figure that makes the dose-response clear: each 1-point increase in the sitting-rising score was linked to a 21% improvement in survival. Not a threshold, not a pass mark — a steady improvement, point by point, across the whole scale.
Read the two studies together and the picture is consistent. The 2012 study, with 2,002 people and 6 years of follow-up, found the lowest scorers dying at more than five times the adjusted rate of the highest. The 2025 study, with 4,282 people and 12 years, found the lowest scorers dying at nearly four times the adjusted rate for natural causes and six times for cardiovascular disease. The numbers differ because the studies differ — different group sizes, different follow-up lengths, different score bands, different adjustments — but they point the same way. A test that takes a minute, needs no equipment, and asks nothing more than sitting down and standing up, separated the people who would die in the next decade from the people who would not, in two different decades, in the same clinic.
The Chair Version: 43,605 People Across 28 Countries
The floor test is striking, but it has an obvious limit: it was run in one clinic, in one city, in one country. The people who walked into CLINIMEX in Rio de Janeiro were mostly white, mostly well-off, and well enough to attend an exercise clinic. That does not make the result wrong, but it does make it narrow. The chair version of the test answers that objection, because it has been run at a scale the floor test has never reached — in tens of thousands of people, across most of a continent.
The largest chair-stand study in this article comes from SHARE, the Survey of Health, Ageing and Retirement in Europe, and was published in the Brazilian Journal of Physical Therapy in late 2025. It included 43,605 community-dwelling adults aged 50 and older, with a mean age of 65.3 years and 54% women, followed for a mean of 7.3 years. In that time, 4,154 people died — 9.5% of the group. The test was the 5-repetition chair stand: sit in a chair, cross your arms, stand up and sit down five times, timed in seconds.
The researchers also measured handgrip strength in the same people, and compared the two tests head to head — which makes this study the most honest one in the article, because it does not flatter the chair stand. Both tests were linked to mortality in a curved, dose-response pattern: the risk fell steeply as performance improved from the slowest and weakest, then flattened out. Using the median chair-stand time of 11 seconds as the reference point:
| 5-repetition chair stand (Núñez-Cortés et al. 2025, 43,605 people, mean 7.3 years) | Time | Adjusted hazard ratio vs median (11 s) | What it means |
|---|---|---|---|
| Fastest tenth (10th percentile) | 7 s | 0.74 (95% CI 0.69–0.80) | 26% lower mortality risk |
| Median (reference) | 11 s | 1.00 | The comparison point |
| Slowest tenth (90th percentile) | 18 s | 1.18 (95% CI 1.14–1.22) | 18% higher mortality risk |
Now the honest comparison. In the same 43,605 people, handgrip strength predicted mortality more strongly than the chair stand did. Using the median grip of 33 kg as the reference, the weakest tenth (21 kg) carried a hazard ratio of 1.62 (95% CI 1.50–1.75) — a 62% higher risk — while the strongest tenth (51 kg) carried a hazard ratio of 0.58 (0.52–0.64), a 42% lower risk. The chair stand’s spread, from 0.74 to 1.18, is narrower than grip’s, from 0.58 to 1.62. The study’s own conclusion says it plainly: both tools provide valuable information, but handgrip strength may be more relevant for identifying increased mortality risk — while the 5-repetition chair stand may be especially useful in women, where its association with mortality was strongest.
That is not a weakness of this article. It is the point of it. The grip strength post in this series reported the same hierarchy from the other side: across the PURE study of 139,691 adults in 17 countries, UK Biobank’s half a million adults, and a meta-analysis of 42 cohorts covering 3 million people, each 5 kg lower grip strength was linked to about 16% higher mortality. Grip is the stronger single predictor. The chair stand still matters, because it measures something grip cannot: the legs, the hips, the ability to get out of a chair — the movements that decide whether a person can live independently. A strong hand does not get you out of a chair. Strong legs do.
There is one more reason the chair version matters. The floor test excludes people who cannot get on the floor — which is most of the people a clinician most wants to assess. The chair test does not. It can be done by almost anyone who can sit in a chair, which is why the CDC uses it as a screening tool, and why the largest studies use it. The floor test is the more dramatic predictor. The chair test is the more usable one.
The Hypertension Study: 18,252 People
A second SHARE study, published in Maturitas in May 2025, asked the same chair-stand question in a narrower group: adults with high blood pressure. It included 18,252 adults aged 50 and older with hypertension, from 28 countries — 27 European countries plus Israel — and followed them for a mean of 3.5 years. In that time, 648 people died, of whom 243 died from cardiovascular disease.
The test was the same five chair stands, timed. The median time was again 11 seconds. And the result was the same shape as the larger study, with one difference worth noting: the follow-up was short, just 3.5 years on average, so the numbers are less settled than the 7.3-year study above.
| 5-repetition chair stand (Polo-López et al. 2025, 18,252 people with hypertension, mean 3.5 years) | Time | All-cause mortality | Cardiovascular mortality |
|---|---|---|---|
| Fastest tenth (10th percentile) | 7 s | HR 0.71 (0.60–0.85) — 29% lower risk | SHR 0.72 (0.53–0.97) — 28% lower risk |
| Median (reference) | 11 s | 1.00 | 1.00 |
| Slowest tenth (90th percentile) | 19 s | HR 1.20 (1.10–1.32) — 20% higher risk | SHR 1.28 (1.10–1.48) — 28% higher risk |
Two caveats belong with this study, and the article states them rather than burying them. First, everyone in it had hypertension. The results describe people with high blood pressure, not all adults, and they should not be generalised beyond that group without saying so. Second, the follow-up is short. Three and a half years is enough to see a signal, but not enough to be sure how it holds up over a decade — the floor test’s 12.3 years is the long view, and this study is the short one. What it adds is breadth: 28 countries, one test, the same direction. Faster chair stands went with lower mortality, in people with hypertension as in the general population, for death from any cause and for cardiovascular death alike.
What the Test Actually Measures
Standing up from the floor, or from a chair, looks like one movement. It is at least five things happening at once, and the test is useful precisely because it asks all five to cooperate — and fails when any one of them falls short.
First, leg strength. The quadriceps at the front of the thigh and the glutes at the hip do the heavy lifting. Getting out of a chair, or off the floor, means moving your whole body weight upward from a deep position, and that takes force. Weak legs make the movement slow, or make it impossible without a hand on something.
Second, power — which is strength applied quickly. The chair test is timed, and the floor test rewards a smooth, controlled rise. Power fades faster with age than strength does, and it is power, more than strength, that decides whether you can catch yourself when you trip, or get up quickly enough to answer the door.
Third, flexibility. To sit on the floor and rise without support, your ankles, hips and spine have to bend through a large range of motion. Stiff ankles, tight hips or a stiff lower back all cost points on the sitting-rising test — not because you are weak, but because you cannot get into the positions the movement needs.
Fourth, balance. Rising from the floor means shifting your weight over a small base of support, with nothing to hold on to. The test deducts half a point for an unsteady execution, and that half point is the balance system showing up in the score: the inner ear, the eyes, and the small muscles of the ankle and foot making corrections you never notice until they fail.
Fifth, body composition. The test asks you to lift your own weight. A heavier body makes the same movement harder, and the researchers who designed the test say so themselves: the score is influenced by muscular strength and power, flexibility, balance and body composition, all at once.
That is why researchers call tests like this one summary measures — the same word used for walking speed and for the one-leg stand. They do not test one organ. They test the whole system doing one of its daily jobs. A grip-strength test isolates the hand. A VO2 max test isolates the heart and lungs at full effort. A sit-to-stand test watches the entire body get itself off the floor, and the number that comes out is the sum of everything that went into it.
It also explains why the test tracks mortality without causing it. Nothing about sitting and rising kills anyone. What the test does is reveal, in one minute, how much reserve a person’s body has left — how much strength, flexibility, balance and power remain after age, illness and inactivity have taken their share. People with little reserve die sooner, from the ordinary causes that kill most people: heart disease, cancer, respiratory disease. The test does not predict one disease. It predicts the body’s margin, and the margin predicts survival.
Sit-to-Stand vs the Other Longevity Numbers
This is the seventh post in the longevity-marker series, and it is worth putting the sit-to-stand test next to the six that came before it — not to rank them, but to show what each one measures, and why they agree with each other even though they test different things.
| Marker | What it measures | Headline study | Headline finding |
|---|---|---|---|
| VO2 Max | Cardiorespiratory fitness — heart, lungs and muscles at full effort | Synthesis of more than 20 million observations | High fitness: about 53% lower mortality than low fitness; each 1-MET higher: 11–17% lower risk |
| Grip Strength | Hand and overall muscle strength | PURE, 139,691 adults, 17 countries; UK Biobank, ~500,000; meta-analysis, 42 cohorts, 3 million people | Each 5 kg lower grip: about 16% higher mortality |
| Resting Heart Rate | Heart rate at rest | Meta-analysis, 46 studies, 1,246,203 people | Each 10 bpm higher: 9% higher mortality; above 80 bpm: 45% higher |
| Heart Rate Variability | Variation between heartbeats — autonomic balance | Meta-analysis 2022, 38,008 people | Lowest quarter of HRV: 56% higher mortality |
| Walking Speed | Usual walking pace | October 2026 study, 4,067 adults, median 11.8 years; classic pooled analysis, 34,485 people | Each 0.1 m/s faster: about 10–12% lower mortality |
| One-Leg Stand | Static balance | Araújo 2022, 1,702 people; Wu 2026, 13,423 people | Failing the 10-second stand: 17.5% died vs 4.6% who passed; best fifth in Wu 2026: 50% lower mortality |
| Sit-to-Stand (this post) | Leg strength, power, flexibility, balance, body composition | Araújo 2025, 4,282 people, median 12.3 years; SHARE, 43,605 people | Score 10: 3.7% died vs 42.1% at scores 0–4; adjusted HR 3.84 natural, 6.05 cardiovascular |
Three things stand out from that table. First, the sit-to-stand test has the largest adjusted hazard ratios of any marker in the series — 3.84 and 6.05, against 1.84 for failing the one-leg stand and 1.62 for the weakest grip. But that comparison is not quite fair: the floor test compares the worst tenth with the perfect scorers, while most of the other markers compare fifths or a 5 kg step. The size of a hazard ratio depends on how extreme the comparison is, and the floor test’s comparison is the most extreme in the series.
Second, the markers agree with each other because they are measuring overlapping systems. The Wu 2026 study, which measured seven fitness tests in the same 13,423 people, found that the composite of all seven tests predicted mortality better than any single test — an adjusted hazard ratio of 0.39 for the best fifth against the worst, against 0.55 for the 30-second chair stand alone, 0.50 for the one-leg stance and 0.41 for the 8-foot up-and-go. No single number captures the whole body. The series exists because the body is not one number.
Third, the sit-to-stand test is the most practical of the markers that need no equipment. VO2 max needs a lab or a good watch estimate. Grip strength needs a dynamometer. Resting heart rate and HRV need a wearable. The chair stand needs a chair and a stopwatch, and the floor test needs a floor. That is why the CDC puts the 30-second chair stand in its fall-prevention toolkit, and why the test turns up in clinics that have nothing else to measure with.
What the Studies Cannot Tell You
Every number in this article comes with limits, and the honest version of the article states them before the reader has to find them.
The evidence is observational. Every study cited here watched people and recorded what happened. None of them assigned people to practise the test, or to train their leg strength, and then measured whether they lived longer. So no study in this article shows that improving your sit-to-stand score reduces your risk of dying. It shows that people who score better live longer — which is a different claim, and a weaker one, because healthier people score better for many reasons at once.
Reverse causation is real. Illness damages the test before it kills the person. A heart condition, an undiagnosed cancer, arthritis, a neurological problem — all of them make it harder to rise from the floor, and all of them shorten life. Some of the gap between high and low scorers is the test detecting illness that is already there, not predicting illness that is coming. The studies adjust for age, sex, body mass and known clinical variables, but adjustment can only remove what the researchers measured. It cannot remove what they did not.
The floor test’s population is narrow. The 4,282 people in the 2025 study, and the 2,002 in the 2012 study, came from a single private exercise clinic in Rio de Janeiro. They were mostly men (68%), mostly white, mostly from higher socioeconomic groups, and all of them were well enough to attend an exercise clinic and to get on the floor. The results describe that population. They may not describe everyone, and the SHARE chair-stand studies — 43,605 people across 28 countries, and 18,252 people with hypertension — are the evidence that the signal survives in a broader population, in the chair version at least. For the floor version, the broad-population evidence does not yet exist.
The hypertension study is narrow in a different way. Everyone in it had high blood pressure, and the follow-up averaged only 3.5 years. Its results describe people with hypertension over a short period, not all adults over a decade. The article cites it for breadth across countries, not as a general-population finding.
The CDC cut-offs are fall-risk values, not mortality targets. The 30-second chair stand scores in the CDC’s STEADI form — fewer than 14 stands for men aged 60 to 64, fewer than 12 for women the same age — mark below-average performance and a risk of falls. They are screening values for adults aged 60 to 94. They are not mortality targets, they do not exist for anyone under 60 or over 94, and this article does not present them as a number to reach.
No study sets a personal target. Not the floor test, not the chair test. A score of 10, a time of 11 seconds, a count of 14 stands — these are study results in specific age groups, not instructions. A single result says nothing certain about any one person, and this article does not invent a line to cross.
Myths vs Facts
Myth: If you can stand up from the floor without using your hands, you will live longer. Fact: The studies show that people who can do this live longer on average. They do not show that doing it causes a longer life, or that practising it adds years. No trial has tested that, and this article does not claim it.
Myth: A score of 10 on the sitting-rising test means you are healthy. Fact: A score of 10 means you sat and rose cleanly in a clinic, on one day. In the 2025 study, 3.7% of the perfect scorers still died during follow-up. A good score is a good sign, not a guarantee — and the study’s participants were aged 46 to 75, so the number says nothing about younger or older people.
Myth: The chair stand and the floor test are the same test. Fact: They share a name — sit-to-stand — and a movement, but they measure different things in different units. The floor test gives a score out of 10 with no stopwatch. The 5-repetition chair stand gives a time in seconds. The 30-second chair stand gives a count. A score of 8, a time of 11 seconds and a count of 12 are not interchangeable, and the studies behind them are different studies.
Myth: The slowest chair stand means you are about to fall. Fact: A slow chair stand, or a below-average 30-second count, is linked to a higher risk of falls — that is what the CDC’s cut-offs are for. But risk is not certainty. In the SHARE study of 43,605 people, the slowest tenth carried an 18% higher mortality risk than the middle, not a sentence. A single slow result is a reason to mention it to a clinician, not a reason to panic.
Myth: Grip strength is the only test that matters, so the chair stand is pointless. Fact: In the 43,605-person SHARE study, grip strength did predict mortality more strongly than the chair stand. But the same study concluded that both tools are valuable, and that the chair stand was especially useful in women. Grip measures the hand. The chair stand measures the legs getting you out of a chair. Different tools, different jobs — and the Wu 2026 study found that combining seven tests predicted mortality better than any one of them alone.
Myth: You need a gym or a trainer to test yourself. Fact: The floor test needs a floor and two square metres. The chair test needs a sturdy chair without armrests and a stopwatch. That is the whole equipment list. But needing no equipment is not the same as being safe to try alone — the floor test is done barefoot on a non-slippery surface, near support, and the researchers advise against doing it unsupervised, especially with joint problems, dizziness or an unstable gait.
Interesting Facts
- The sitting-rising test was designed by the same researcher, Claudio Gil Araújo, whose clinic also produced the 10-second one-leg stand study in this series. One clinic, two tests, both now among the most-cited simple fitness tests in the mortality literature.
- The scoring has a quirk that tells you what the test values: crossing your legs is allowed, but using the side of your foot as a support is not. The test rewards flexibility and control, not cleverness.
- The 2025 study’s plain-language summary puts it bluntly: the death rate was 3.7% for a perfect score, tripled to 11.1% at a score of 8, and reached 42.1% in the lowest group. Those are raw rates — the adjusted hazard ratios, 3.84 and 6.05, are the study’s careful version of the same gap.
- The chair-stand test is old enough to be a standard: the CDC’s STEADI form dates from 2017, and the reference values it uses come from normative data collected in the 1990s. The mortality evidence for it, by contrast, is brand new — both SHARE studies were published in 2025.
- In the Wu 2026 study of 13,423 adults, the 30-second chair stand was one of seven tests, and the composite of all seven beat every single test. The chair stand alone gave an adjusted hazard ratio of 0.55 for the best fifth; the composite gave 0.39.
- The floor test’s participants were assessed over 25 years, from 1998 to 2023, and followed for a median of 12.3 years. The study published in 2025 is, in a real sense, a quarter of a century of clinic work.
- The slowest tenth in the SHARE chair-stand study took 18 seconds for five stands. The fastest tenth took 7 seconds. Eleven seconds separated the two ends of the distribution — and a 26% lower mortality risk at one end from an 18% higher risk at the other.
How Researchers Do the Tests
If you read the studies, the protocols are precise — and the precision is the point. A test that is done differently every time cannot be compared across studies, so each version has a fixed procedure. This section describes what the researchers did. It is not an instruction to try the tests yourself, and the safety note at the end is part of the procedure, not an afterthought.
| Feature | Floor sitting-rising test (SRT) | 5-repetition chair stand (5-CST) | 30-second chair stand |
|---|---|---|---|
| Equipment | Bare floor, non-slippery surface, about 2×2 m | Straight-backed chair, stopwatch | Straight-backed chair without armrests (seat 17″ high), stopwatch |
| Starting position | Standing, barefoot | Seated, arms crossed on opposite shoulders, feet flat, back straight | Seated, arms crossed on opposite shoulders, feet flat, back straight |
| What you do | Sit on the floor, then rise — no support | Stand up and sit down 5 times, as fast as you can | Stand up and sit down as many times as you can in 30 seconds |
| Scoring | 0–10: 5 for sitting + 5 for rising; −1 per support used; −0.5 for unsteadiness | Time in seconds (median 11 s in SHARE) | Count of full stands; more than halfway up when time ends counts |
| If you use your arms | Lose 1 point per support | Not part of the timed protocol | Stop the test, record 0 |
| Result recorded | Score in five bands: 0–4, 4.5–7.5, 8, 8.5–9.5, 10 | Time, compared with the median | Count, compared with the age/sex cut-offs below |
| Used for | Mortality research (Araújo 2012, 2025) | Mortality research (SHARE 2025 ×2) | CDC STEADI fall-risk screening |
The CDC’s below-average scores for the 30-second chair stand — the only version of the test with published age and sex cut-offs — are a fall-risk screen, not a mortality target. A score below the line for your age and sex means your leg strength and endurance are below average for your group, and that carries a risk of falls.
| Age | Men: below average | Women: below average |
|---|---|---|
| 60–64 | Fewer than 14 stands | Fewer than 12 stands |
| 65–69 | Fewer than 12 stands | Fewer than 11 stands |
| 70–74 | Fewer than 12 stands | Fewer than 10 stands |
| 75–79 | Fewer than 11 stands | Fewer than 10 stands |
| 80–84 | Fewer than 10 stands | Fewer than 9 stands |
| 85–89 | Fewer than 8 stands | Fewer than 8 stands |
| 90–94 | Fewer than 7 stands | Fewer than 4 stands |
There are no cut-offs below age 60 or above age 94, because the reference data do not cover those ages. And the safety note matters more than the table. The floor test was done in a clinic, barefoot, on a non-slippery surface, with examiners present and support nearby, in people who had no locomotor complaints that would have made it unsafe. The test’s own researchers advise against doing the floor version unsupervised. The chair version is the safer one to describe — a sturdy chair against a wall, arms crossed, someone nearby — and even then, it is not for people with joint problems, dizziness or an unstable gait. If your ability to stand has changed, or you have started falling, that is worth mentioning to a clinician at a routine appointment, rather than testing yourself alone.
Frequently Asked Questions
What Is a Good Sit-to-Stand Result?
There is no single good number, because there are three tests and they are scored differently. On the floor test, the studies grouped people into bands — 10, 8.5–9.5, 8, 4.5–7.5 and 0–4 — and the death rate rose across them, from 3.7% to 42.1% over 12 years. On the 5-repetition chair stand, the middle time in the SHARE studies was 11 seconds, with the fastest tenth at 7 seconds and the slowest at 18 or 19 seconds. On the 30-second chair stand, the CDC lists below-average scores by age and sex for adults aged 60 to 94 — for example, fewer than 14 stands for men aged 60 to 64. None of these is a target you must reach. They are study results in specific age groups, and this article does not invent a line to cross.
Can I Try the Sit-to-Stand Test at Home?
The studies did the tests under supervision, with examiners present and support nearby. This article describes what the researchers did; it does not turn the tests into home challenges. The floor version in particular is done barefoot on a non-slippery surface, near support, and its researchers advise against trying it unsupervised — especially if you have joint problems, dizziness or an unstable gait. If you want to know how your leg strength and balance are doing, the safest route is to mention it at a routine check-up, where a clinician can watch you stand, check the things that affect it — strength, vision, medication, joint problems — and decide whether any follow-up is needed. Do not test yourself alone if you feel unsteady, and stop immediately if you feel pain or dizziness.
Will Practising Sit-to-Stand Make Me Live Longer?
No study in this article proves that. The evidence is observational: people who score better live longer, but healthier people score better for many reasons, and illness itself damages the score. What trials do show is narrower and still useful: exercise reduced the overall rate of falls by approximately 23% in trial populations, according to the Cochrane review cited by the WHO, and the WHO estimates about 842,000 deaths from falls worldwide in 2023, with about 71% among adults aged 60 and older. Fewer falls is a real benefit. Longer life from practising the test is not a finding in any study cited here, and this article does not claim it.
Why Do the Studies Give Different Numbers?
Because they asked the question differently. The floor test scored people from 0 to 10 and compared the lowest group with the perfect scorers, giving adjusted hazard ratios of 3.84 and 6.05. The chair-stand studies timed five stands and compared the fastest and slowest tenths with the median, giving hazard ratios of 0.74 and 1.18. A lowest-versus-perfect comparison and a fastest-versus-median comparison are different comparisons, in different age groups, in different countries, with different tests. The numbers cannot be placed side by side. What can be compared is the direction — and in every study in this article, better performance went with lower mortality.
Which Test Matters Most — the Floor Test or the Chair Test?
They answer different questions. The floor test has the longest follow-up and the largest adjusted hazard ratios: 12.3 years, 4,282 people, 3.84 for natural mortality. The chair test has the broadest population: 43,605 people across 28 countries in SHARE, and a place in the CDC’s fall-prevention toolkit. The floor test is the stronger predictor in the populations studied; the chair test is the one a clinic can actually use with almost anyone. And in the SHARE study that measured both, grip strength predicted mortality slightly more strongly than the chair stand — while the chair stand was especially useful in women. No single test wins. The honest answer is that they measure different parts of the same system, and the system is what matters.
Medical Disclaimer
This article is for general information only. It is not medical advice, and it is not a substitute for professional medical advice, diagnosis, or treatment. Sit-to-stand results are population research findings, not diagnoses for any individual. A low score does not mean you are ill, and a perfect score does not mean you are healthy. The floor sitting-rising test should not be attempted unsupervised, especially if you have joint problems, dizziness, or an unstable gait. If your ability to stand or walk has changed, you feel unsteady, or you have had a fall, speak to a qualified clinician promptly. Always consult a healthcare professional before starting a new exercise programme, especially if you have a medical condition. The author is a research writer, not a licensed medical clinician.
Sources
- Araújo CGS, de Souza E Silva CG, Myers J, Laukkanen JA, Ramos PS, Ricardo DR. Sitting-rising test scores predict natural and cardiovascular causes of deaths in middle-aged and older men and women. European Journal of Preventive Cardiology. 2026;33(12):2170–2178. Published online 18 June 2025. DOI 10.1093/eurjpc/zwaf325. PubMed PMID 40569873
- Brito LBB, Ricardo DR, Araújo DSMS, Ramos PS, Myers J, Araújo CGS. Ability to sit and rise from the floor as a predictor of all-cause mortality. European Journal of Preventive Cardiology. 2014;21(7):892–898. Published online 13 December 2012. DOI 10.1177/2047487312471759. PubMed PMID 23242910
- Núñez-Cortés R, Andersen LL, Cruz-Montecinos C, Polo-López A, López-Bueno R, Calatayud J. Five-repetition chair-stand test vs. handgrip strength: Which better predicts mortality risk? A follow-up study in 43,605 middle-aged and older adults. Brazilian Journal of Physical Therapy. 2025;29(6):101529. DOI 10.1016/j.bjpt.2025.101529. PubMed PMID 40992236
- Polo-López A, López-Bueno R, Calatayud J, Núñez-Cortés R, Suso-Martí L, Andersen LL. Association of chair stand performance with all-cause and cardiovascular mortality in older adults with hypertension: A 28-country study. Maturitas. 2025;196:108248. DOI 10.1016/j.maturitas.2025.108248. PubMed PMID 40147230
- Centers for Disease Control and Prevention. STEADI — Assessment: 30-Second Chair Stand. 2017. CDC STEADI 30-Second Chair Stand (PDF)
- Wu MC, et al. Physical Fitness and All-Cause Mortality in Older Adults. JAMA Network Open. 2026;9(8):e2628227. Published online 10 August 2026. DOI 10.1001/jamanetworkopen.2026.28227. JAMA Network Open
- World Health Organization. Falls (fact sheet). Updated 21 October 2026. Approximately 842,000 deaths from falls worldwide in 2023; about 71% among adults aged 60 and older; exercise reduced the overall rate of falls by approximately 23% in trial populations (Cochrane). WHO Falls
This article is for informational and educational purposes only. It does not constitute medical advice, diagnosis, or treatment. The information presented is researched from trusted sources including peer-reviewed scientific journals, CDC, NIH, WHO, and recognized health organizations. Always consult a qualified healthcare professional before making any changes to your diet, exercise routine, or health regimen.